Recent questions tagged single-line-diagram
0
votes
0
answers
1
GATE Electrical 2014 Set 1 | Question: 40
A distribution feeder of $1\:km$ length having resistance, but negligible reactance, is fed from both the ends by $400V$, $50\:Hz$ balanced sources. Both voltage sources $S_1$ and $S_2$ are in phase. The feeder supplies concentrated loads of unity power factor as shown in the figure. ... $25\:A$ $50\:A$ and $50\:A$ $25\:A$ and $75\:A$ $0\:A$ and $100\:A$
A distribution feeder of $1\:km$ length having resistance, but negligible reactance, is fed from both the ends by $400V$, $50\:Hz$ balanced sources. Both voltage sources ...
makhdoom ghaya
9.4k
points
makhdoom ghaya
asked
Feb 11, 2017
Power Systems
gate2014-ee-1
single-line-diagram
distribution
feeder
+
–
0
votes
0
answers
2
GATE Electrical 2014 Set 1 | Question: 15
Three-phase to ground fault takes place at locations $F_1$ and $F_2$ in the system shown in the figure If the fault takes place at location $F_1$, then the voltage and the current at bus $A$ are $V_{F1}$ and $I_{F1}$ respectively. If the fault takes place at location ... $I_{F1}$ and $V_{F2}$ leads $I_{F2}$ $V_{F1}$ lags $I_{F1}$ and $V_{F2}$ lags $I_{F2}$
Three-phase to ground fault takes place at locations $F_1$ and $F_2$ in the system shown in the figureIf the fault takes place at location $F_1$, then the voltage and the...
makhdoom ghaya
9.4k
points
makhdoom ghaya
asked
Feb 11, 2017
Power Systems
gate2014-ee-1
single-line-diagram
power-factor
+
–
0
votes
0
answers
3
GATE Electrical 2015 Set 1 | Question: 44
A sustained three-phase fault occurs in the power system shown in the figure. The current and voltage phasors during the fault (on a common reference), after the natural transients have died down, are also shown. Where is the fault located? Location $P$ Location $Q$ Location $R$ Location $S$
A sustained three-phase fault occurs in the power system shown in the figure. The current and voltage phasors during the fault (on a common reference), after the natural ...
makhdoom ghaya
9.4k
points
makhdoom ghaya
asked
Feb 11, 2017
Power Systems
gate2015-ee-1
single-line-diagram
fault-analysis
+
–
1
votes
0
answers
4
GATE Electrical 2016 Set 2 | Question: 38
The single line diagram of a balanced power system is shown in the figure. The voltage magnitude at the generator internal bus is constant and $1.0$ p.u. The p.u. reactances of different components in the system are ... transferred during the pre-fault condition to the maximum real power that can be transferred under the faulted condition is _________.
The single line diagram of a balanced power system is shown in the figure. The voltage magnitude at the generator internal bus is constant and $1.0$ p.u. The p.u. reactan...
makhdoom ghaya
9.4k
points
makhdoom ghaya
asked
Jan 29, 2017
Power Systems
gate2016-ee-2
single-line-diagram
three-phase-fault
pre-fault-condition
numerical-answers
+
–