Login
Register
Dark Mode
Brightness
Ambient Glow – Questions list
Register
Profile
Edit Profile
Messages
My favorites
My Updates
Logout
Recent questions tagged power-factor
0
0 votes
0
0 answers
356
356 views
GATE Electrical 2025 | Question: 53
Using shunt capacitors, the power factor of a $3$ -phase, $4 \: \mathrm{ kV}$ induction motor (drawing $390 \: \mathrm{kVA}$ at $0.77$ pf lag ) is to be corrected to $0.8...
Shubham Sharma 2
356
views
asked
Mar 6, 2025
Power Systems
gate2025-ee
numerical-answers
power-systems
power-factor
electric-circuits
+
–
0
0 votes
0
0 answers
891
891 views
GATE Electrical 2022 | Question: 14
The type of single-phase induction motor, expected to have the maximum power factor during steady state running condition, issplit phase (resistance start).shaded pole.ca...
Arjun
891
views
asked
Feb 15, 2022
new
gate2022-ee
electrical-machines
power-factor
+
–
0
0 votes
0
0 answers
644
644 views
GATE Electrical 2022 | Question: 23
The voltage at the input of an $\text{AC-DC}$ rectifier is given by $v\left ( t \right ) = 230 \sqrt{2} \sin \omega t$ where $\omega = 2\pi \times 50$ rad/s. The input cu...
Arjun
644
views
asked
Feb 15, 2022
Power Electronics
gate2022-ee
numerical-answers
power-electronics
power-factor
+
–
0
0 votes
0
0 answers
393
393 views
GATE Electrical 2012 | Question: 52
In the circuit shown, the three voltmeter readings are $V_1 =220$ V, $V_2=122$ V, $V_3=136$ V.The power factor of the load is$0.45$$0.50$$0.55$$0.60$
Andrijana3306
393
views
asked
Mar 23, 2018
Electric Circuits
gate2012-ee
electric-circuits
power-factor
+
–
0
0 votes
0
0 answers
241
241 views
GATE Electrical 2017 Set 2 | Question: 48
In the circuit shown in the figure, the diode used is ideal. The input power factor is ________. (Give the answer up to two decimal places).
Arjun
241
views
asked
Feb 26, 2017
Power Electronics
gate2017-ee-2
numerical-answers
power-electronics
power-factor
+
–
0
0 votes
0
0 answers
191
191 views
GATE Electrical 2017 Set 1 | Question: 39
A load is supplied by a $230$ V, $50$ Hz source. The active power $P$ and the reactive power $Q$ consumed by the load are such that $1kW \leq P \leq 2kW$ and $1kVAR \leq ...
Arjun
191
views
asked
Feb 26, 2017
Power Systems
gate2017-ee-1
power-systems
power-factor
numerical-answers
+
–
0
0 votes
0
0 answers
300
300 views
GATE Electrical 2014 Set 2 | Question: 53
A fully controlled converter bridge feeds a highly inductive load with ripple free load current. The input supply $(V_s)$ to the bridge is a sinusoidal source. Triggering...
Misbah Ghaya
300
views
asked
Feb 11, 2017
Electrical and Electronic Measurements
gate2014-ee-2
power-factor
converters
numerical-answers
+
–
0
0 votes
0
0 answers
294
294 views
GATE Electrical 2014 Set 2 | Question: 20
While measuring power of a three-phase balanced load by the two-wattmeter method, the readings are $100$ $W$ and $250$ $W$. The power factor of the load is ______.
Misbah Ghaya
294
views
asked
Feb 11, 2017
Power Systems
gate2014-ee-2
balanced-loads
power-factor
numerical-answers
+
–
0
0 votes
0
0 answers
247
247 views
GATE Electrical 2014 Set 2 | Question: 15
A three phase star-connected load is drawing power at a voltage of $0.9$ $pu$ and $0.8$ power factor lagging. The three phase base power and base current are $100$ $MVA$ ...
Misbah Ghaya
247
views
asked
Feb 11, 2017
Power Systems
gate2014-ee-2
power-factor
star-connection
numerical-answers
+
–
0
0 votes
0
0 answers
297
297 views
GATE Electrical 2014 Set 1 | Question: 15
Three-phase to ground fault takes place at locations $F_1$ and $F_2$ in the system shown in the figureIf the fault takes place at location $F_1$, then the voltage and the...
Misbah Ghaya
297
views
asked
Feb 11, 2017
Power Systems
gate2014-ee-1
single-line-diagram
power-factor
+
–
0
0 votes
0
0 answers
344
344 views
GATE Electrical 2015 Set 2 | Question: 30
The coils of a wattmeter have resistances $0.01 \Omega$ and $1000 \Omega$; their inductances may be neglected. The wattmeter is connected as shown in the figure, to measu...
Misbah Ghaya
344
views
asked
Feb 11, 2017
Electric Circuits
gate2015-ee-2
power-measurement
coils
power-factor
numerical-answers
+
–
0
0 votes
0
0 answers
354
354 views
GATE Electrical 2016 Set 2 | Question: 41
The power consumption of an industry is $500$ kVA, at $0.8$ p.f. lagging. A synchronous motor is added to raise the power factor of the industry to unity. If the power in...
Misbah Ghaya
354
views
asked
Jan 29, 2017
Power Systems
gate2016-ee-2
synchronous-motor
power-factor
power-intake
numerical-answers
+
–
To see more, click for the
full list of questions
or
popular tags
.