A single-phase transmission line has two conductors each of $10$ mm radius. These are fixed at a center-to-center distance of $1$ m in a horizontal plane. This is now converted to a three-phase transmission line by introducing a third conductor of the same radius. This conductor is fixed at an equal distance $D$ from the two single-phase conductors. The three-phase line is fully transposed. The positive sequence inductance per phase of the three-phase system is to be $5\%$ more than that of the inductance per conductor of the single-phase system. The distance $D$, in meters, is _________.

Please log in or register to answer this question.

Related questions

0 0 votes
0 0 answers
272
272 views
Misbah Ghaya asked Jan 29, 2017
272 views
A $30 MVA$, $3$-phase, $50 Hz$, $13.8 kV$, star-connected synchronous generator has positive, negative and zero sequence reactances, $15\%$, $15\%$ and $5\%$ respectively...
0 0 votes
0 0 answers
255
255 views
Misbah Ghaya asked Jan 29, 2017
255 views
A three-phase cable is supplying $800 kW$ and $600 kVAr$ to an inductive load. It is intended to supply an additional resistive load of $100 kW$ through the same cable wi...
0 0 votes
0 0 answers
350
350 views
Misbah Ghaya asked Jan 29, 2017
350 views
The magnitude of three-phase fault currents at buses $A$ and $B$ of a power system are $10$ pu and $8$ pu, respectively. Neglect all resistances in the system and conside...
0 0 votes
0 0 answers
764
764 views
Misbah Ghaya asked Jan 29, 2017
764 views
The circuit below is excited by a sinusoidal source. The value of $R$, in $\Omega$, for which the admittance of the circuit becomes a pure conductance at all frequencies ...
Position:
Show:
Answer: