GO Electrical
Login
Register
Dark Mode
Brightness
Profile
Edit Profile
Messages
My favorites
My Updates
Logout
Recent questions tagged reactive-power
0
votes
0
answers
1
GATE Electrical 2013 | Question: 8
A single-phase load is supplied by a single-phase voltage source. If the current flowing from the load to the source is $10\angle -150^0\: A$ and if the voltage at the load terminals is $100\angle 60^0\: V$, ... absorbs real power and absorbs reactive power. Load delivers real power and delivers reactive power. Load delivers real power and absorbs reactive power.
A single-phase load is supplied by a single-phase voltage source. If the current flowing from the load to the source is $10\angle -150^0\: A$ and if the voltage at the lo...
piyag476
1.6k
points
piyag476
asked
Feb 11, 2017
Power Systems
gate2013-ee
reactive-power
real-power
+
–
0
votes
0
answers
2
GATE Electrical 2016 Set 1 | Question: 48
A three-phase, $50 Hz$ salient-pole synchronous motor has a per-phase direct-axis reactance $(X_{d})$ of $0.8$ pu and a per-phase quadrature-axis reactance $(X_{q})$ of $0.6$ pu. Resistance of the machine is negligible. It is drawing full-load current at $0.8$ pf(leading). When the terminal voltage is $1$ pu, per-phase induced voltage, in pu, is _______.
A three-phase, $50 Hz$ salient-pole synchronous motor has a per-phase direct-axis reactance $(X_{d})$ of $0.8$ pu and a per-phase quadrature-axis reactance $(X_{q})$ of $...
makhdoom ghaya
9.4k
points
makhdoom ghaya
asked
Jan 29, 2017
Electrical Machines
gate2016-ee-1
damper-winding
constant-dc-field-winding
reactive-power
numerical-answers
+
–
0
votes
0
answers
3
GATE Electrical 2016 Set 1 | Question: 40
A three-phase cable is supplying $800 kW$ and $600 kVAr$ to an inductive load. It is intended to supply an additional resistive load of $100 kW$ through the same cable without increasing the heat dissipation in the cable, by providing a three- ... voltage is $3.3 kV$, $50 Hz$, the capacitance per phase of the bank, expressed in microfarads, is ________.
A three-phase cable is supplying $800 kW$ and $600 kVAr$ to an inductive load. It is intended to supply an additional resistive load of $100 kW$ through the same cable wi...
makhdoom ghaya
9.4k
points
makhdoom ghaya
asked
Jan 29, 2017
Power Systems
gate2016-ee-1
active-power
reactive-power
heat-losses
numerical-answers
+
–
To see more, click for the
full list of questions
or
popular tags
.
GO Electrical
Email or Username
Show
Hide
Password
I forgot my password
Remember
Log in
Register