A two bus power system shown in the figure supplies load of $1.0+j0.5\: \text{p.u}.$
The values of $V_1$ in $\text{p.u.}$ and $\delta_2$ respectively are
- $0.95$ and $6.00^{\circ}$
- $1.05$ and $-5.44^{\circ}$
- $1.1$ and $-6.00^{\circ}$
- $1.1$ and $-27.12^{\circ}$